🎓 Academic Discount – Enjoy 5% off for universities & research institutions. Publish with our materials? Get an extra 5% off! Please contact us for more information.





Couldn't load pickup availability
Compact mobile incubator with precision temperature control for laboratory and on-site use
The Cell Lab Portable Incubator is a lightweight, PID-controlled mobile incubation unit designed for microbiological, biochemical, agricultural, and medical research tasks. Built with a mirror-finished stainless-steel chamber and optional 12 V DC vehicle power, it enables reliable culture performance anywhere — from laboratory benches to field operations and in-vehicle applications.
• Accurate PID Temperature Control
Intelligent PID controller maintains uniform heating from RT + 5 °C to 65 °C with ± 0.5 °C accuracy and ± 1.5 °C uniformity. Dual-row LED display shows both real-time and setpoint values with 0.1 °C resolution. Built-in timer (up to 9999 min) offers wait, auto-stop, and fixed-time operation.
• Four-Sided Natural Convection Heating
Heating wires embedded on all four inner walls distribute heat evenly without fans, maintaining stable conditions ideal for delicate cultures or biological specimens requiring gentle thermal environments.
• Hygienic Mirror Stainless-Steel Chamber
Rounded arc-corner design prevents residue buildup and simplifies cleaning. Two adjustable shelves (35 mm spacing, 5 kg each) provide flexibility for various containers while ensuring even airflow.
• Observation Window & LED Lighting
Large double-glass window and internal LED illumination allow easy sample observation without opening the door or disrupting temperature stability — ideal for low-light environments and mobile experiments.
• Portable Design with AC/DC Power Compatibility
Compact and easy to carry with a top mounted handle. Operates on AC 220 V / 50 – 60 Hz or optional DC 12 V vehicle adapter, making it suitable for laboratories, field sites, and mobile research vehicles.
|
IB0006 |
IB0007 |
||
|
Cycle Mode |
Natural convection |
||
|
Function |
Tem. Range |
RT+5-65℃ |
|
|
Tem. Resolution Ratio |
0.1℃ |
||
|
Tem. Motion |
±0.5℃ |
||
|
Tem. Uniformity |
±1.5℃ |
||
|
Structure |
Inner Chamber |
Mirror stainless steel |
|
|
Outer Shell |
Cold rolling steel electrostatic spraying exterior |
||
|
Insulation layer |
Polyurethane |
||
|
Heater |
Heating Wire |
||
|
Power Rating |
0.08kW |
0.12kW |
|
|
Controller |
Tem. control mode |
PID Intelligent |
|
|
Tem. setting mode |
Touch button setting |
||
|
Tem. display mode |
Measuring temperature: LED upper row;Setting temperature: the lower row |
||
|
Timer |
0-9999min (with timing wait function) |
||
|
Operation function |
Fixed temperature operation, timing function,auto stop. |
||
|
Additional funciton |
Sensor deviation correction, temperature overshoot self-tuning, internal parameter locking, power-off parameter memory |
||
|
Sensor |
PT100 |
||
|
Safety device |
Over temperature sound-light alarm |
||
|
Specification |
Inner Chamber size(W*L*H)(mm) |
230*200*200 |
230*200*280 |
|
Exterior size (W*L*H)(mm) |
310*276*298 |
310*276*378 |
|
|
Packing size (W*L*H)(mm) |
350*312*377 |
350*312*457 |
|
|
Volume |
9.2L |
12.8L |
|
|
Shelf Number |
2 |
||
|
Load Per Rack |
5kg |
||
|
Shelf Space |
35mm |
||
|
Supply(50/60HZ)Current rating |
AC220V/0.36A |
AC220V/0.36A |
|
|
NW/GW (kg) |
8/10 |
12/14 |
|
|
Optional accessories |
Vehicular/DC12V/AC220VSupply |
||
Field microbial and biochemical research
Agricultural and food-safety sample incubation
On-site industrial and environmental testing
Medical and clinical sample transport incubation
Mobile vehicle-based R&D operations
Q1: Can this unit operate from a car battery?
A1: Yes — the optional DC 12 V adapter allows safe operation in vehicles without performance loss.
Q2: Is temperature distribution uniform without a fan?
A2: Yes — the four-sided heating structure ensures even natural convection and gentle thermal balance.
Q3: Can it be used for field sampling or transport?
A3: Absolutely. Its lightweight body and sturdy construction make it ideal for mobile and off-site research tasks.
Q4: What safety protections are included?
A4: Over-temperature alarm, parameter lock, and power-failure memory prevent sample damage and ensure data security.
Q5: Can the temperature be calibrated by the user?
A5: Yes — sensor deviation correction and self-tuning functions allow precise calibration for different applications.
You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).
You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).
If you need to return an item, simply login to your account, view the order using the "Complete Orders" link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.
We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.
When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.
Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.
Thanks for subscribing!
This email has been registered!