{"product_id":"neware-wgdw-1000-70-environmental-chamber-1000l-70-c-to-150-c","title":"Neware WGDW-1000-70 Environmental Chamber [1000L, -70°C to 150°C]","description":"\u003ch2 data-start=\"14\" data-end=\"83\"\u003e\u003cstrong data-start=\"14\" data-end=\"83\"\u003eNeware WGDW-1000-70 Environmental Chamber [1000L, -70°C to 150°C]\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"85\" data-end=\"239\"\u003eLarge-capacity temperature and humidity test chamber for battery reliability testing, in situ battery analysis, and environmental simulation applications.\u003c\/p\u003e\n\u003chr data-start=\"241\" data-end=\"244\"\u003e\n\u003ch3 data-section-id=\"1sctfkl\" data-start=\"246\" data-end=\"272\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"249\" data-end=\"272\"\u003eGeneral Description\u003c\/strong\u003e\u003c\/span\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"249\" data-end=\"272\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"249\" data-end=\"272\"\u003eThis is quote product, please contact us for the quotation.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"274\" data-end=\"712\"\u003eThe \u003cstrong data-start=\"278\" data-end=\"323\"\u003eNeware WGDW-1000-70 Environmental Chamber\u003c\/strong\u003e is a high-performance temperature and humidity test chamber designed for battery reliability testing, safety validation, and environmental simulation applications. Engineered for lithium-ion battery research and industrial testing environments, the chamber provides stable and precise temperature-humidity control for long-duration battery evaluation and in situ electrochemical analysis.\u003c\/p\u003e\n\u003cp data-start=\"714\" data-end=\"1129\"\u003eWith a large \u003cstrong data-start=\"727\" data-end=\"754\"\u003e1000L internal capacity\u003c\/strong\u003e, the chamber supports testing of battery cells, battery modules, electronic components, semiconductors, and solar cells under controlled environmental conditions. The system features a wide operating temperature range from \u003cstrong data-start=\"978\" data-end=\"996\"\u003e-70°C to 150°C\u003c\/strong\u003e and humidity control from \u003cstrong data-start=\"1023\" data-end=\"1040\"\u003e25% to 98% RH\u003c\/strong\u003e, enabling accelerated ageing tests, thermal cycling, and environmental stress screening.\u003c\/p\u003e\n\u003cp data-start=\"1131\" data-end=\"1525\"\u003eThe chamber includes predrilled cable ports for convenient integration with battery cyclers and external testing systems, allowing real-time in situ battery performance measurement during environmental testing. Built with industrial-grade refrigeration and humidity control systems, the WGDW-1000-70 delivers reliable long-term operation for demanding laboratory and manufacturing applications.\u003c\/p\u003e\n\u003chr data-start=\"1527\" data-end=\"1530\"\u003e\n\u003ch3 data-section-id=\"1j5qwet\" data-start=\"1532\" data-end=\"1551\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1535\" data-end=\"1551\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1553\" data-end=\"1695\"\u003e\u003cstrong data-start=\"1553\" data-end=\"1585\"\u003eLarge 1000L Testing Capacity\u003c\/strong\u003e\u003cbr data-start=\"1585\" data-end=\"1588\"\u003eSpacious internal chamber suitable for battery modules, electronics, and environmental reliability testing.\u003c\/p\u003e\n\u003cp data-start=\"1697\" data-end=\"1836\"\u003e\u003cstrong data-start=\"1697\" data-end=\"1731\"\u003eWide Temperature Control Range\u003c\/strong\u003e\u003cbr data-start=\"1731\" data-end=\"1734\"\u003eSupports environmental simulation from \u003cstrong data-start=\"1773\" data-end=\"1791\"\u003e-70°C to 150°C\u003c\/strong\u003e for thermal cycling and accelerated testing.\u003c\/p\u003e\n\u003cp data-start=\"1838\" data-end=\"1954\"\u003e\u003cstrong data-start=\"1838\" data-end=\"1876\"\u003eIntegrated Humidity Control System\u003c\/strong\u003e\u003cbr data-start=\"1876\" data-end=\"1879\"\u003eHumidity range from \u003cstrong data-start=\"1899\" data-end=\"1916\"\u003e25% to 98% RH\u003c\/strong\u003e for comprehensive climate simulation.\u003c\/p\u003e\n\u003cp data-start=\"1956\" data-end=\"2097\"\u003e\u003cstrong data-start=\"1956\" data-end=\"2001\"\u003ePredrilled Cable Port for In Situ Testing\u003c\/strong\u003e\u003cbr data-start=\"2001\" data-end=\"2004\"\u003eSupports direct cable routing for battery cyclers and real-time electrochemical measurements.\u003c\/p\u003e\n\u003cp data-start=\"2099\" data-end=\"2244\"\u003e\u003cstrong data-start=\"2099\" data-end=\"2145\"\u003eIndustrial-Grade Stability and Reliability\u003c\/strong\u003e\u003cbr data-start=\"2145\" data-end=\"2148\"\u003eDesigned for continuous operation in battery R\u0026amp;D laboratories and industrial testing facilities.\u003c\/p\u003e\n\u003chr data-start=\"2246\" data-end=\"2249\"\u003e\n\u003ch3 data-section-id=\"q11yyz\" data-start=\"2251\" data-end=\"2272\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2254\" data-end=\"2272\"\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2274\" data-end=\"2992\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2274\" data-end=\"2303\"\u003e\n\u003ctr data-start=\"2274\" data-end=\"2303\"\u003e\n\u003cth data-start=\"2274\" data-end=\"2286\" data-col-size=\"sm\" class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2286\" data-end=\"2303\" data-col-size=\"md\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2314\" data-end=\"2992\"\u003e\n\u003ctr data-start=\"2314\" data-end=\"2330\"\u003e\n\u003ctd data-start=\"2314\" data-end=\"2320\" data-col-size=\"sm\"\u003eSKU\u003c\/td\u003e\n\u003ctd data-start=\"2320\" data-end=\"2330\" data-col-size=\"md\"\u003eNW0037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2331\" data-end=\"2355\"\u003e\n\u003ctd data-start=\"2331\" data-end=\"2339\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2339\" data-end=\"2355\"\u003eWGDW-1000-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2356\" data-end=\"2425\"\u003e\n\u003ctd data-start=\"2356\" data-end=\"2371\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2371\" data-end=\"2425\"\u003eAC 380V ±10%, Three-phase five-wire (L1+L2+L3+N+E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2426\" data-end=\"2455\"\u003e\n\u003ctd data-start=\"2426\" data-end=\"2446\" data-col-size=\"sm\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2446\" data-end=\"2455\"\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2456\" data-end=\"2482\"\u003e\n\u003ctd data-start=\"2456\" data-end=\"2474\" data-col-size=\"sm\"\u003eMaximum Current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2474\" data-end=\"2482\"\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2483\" data-end=\"2504\"\u003e\n\u003ctd data-start=\"2483\" data-end=\"2494\" data-col-size=\"sm\"\u003eCapacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2494\" data-end=\"2504\"\u003e1000 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2505\" data-end=\"2549\"\u003e\n\u003ctd data-start=\"2505\" data-end=\"2524\" data-col-size=\"sm\"\u003eOuter Dimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2524\" data-end=\"2549\"\u003e1250 × 1700 × 2150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2550\" data-end=\"2594\"\u003e\n\u003ctd data-start=\"2550\" data-end=\"2569\" data-col-size=\"sm\"\u003eInner Dimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2569\" data-end=\"2594\"\u003e1000 × 1000 × 1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2595\" data-end=\"2614\"\u003e\n\u003ctd data-start=\"2595\" data-end=\"2604\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2604\" data-end=\"2614\" data-col-size=\"md\"\u003e650 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2615\" data-end=\"2635\"\u003e\n\u003ctd data-start=\"2615\" data-end=\"2630\" data-col-size=\"sm\"\u003eShelf Layers\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2630\" data-end=\"2635\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2636\" data-end=\"2674\"\u003e\n\u003ctd data-start=\"2636\" data-end=\"2656\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2656\" data-end=\"2674\"\u003e-70°C to 150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2675\" data-end=\"2709\"\u003e\n\u003ctd data-start=\"2675\" data-end=\"2701\" data-col-size=\"sm\"\u003eTemperature Fluctuation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2701\" data-end=\"2709\"\u003e≤1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2710\" data-end=\"2744\"\u003e\n\u003ctd data-start=\"2710\" data-end=\"2734\" data-col-size=\"sm\"\u003eTemperature Deviation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2734\" data-end=\"2744\"\u003e±2.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2745\" data-end=\"2785\"\u003e\n\u003ctd data-start=\"2745\" data-end=\"2760\" data-col-size=\"sm\"\u003eHeating Time\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2760\" data-end=\"2785\"\u003e-70°C → 150°C ≤95 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2786\" data-end=\"2825\"\u003e\n\u003ctd data-start=\"2786\" data-end=\"2801\" data-col-size=\"sm\"\u003eCooling Time\u003c\/td\u003e\n\u003ctd data-start=\"2801\" data-end=\"2825\" data-col-size=\"md\"\u003e25°C → -70°C ≤90 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2826\" data-end=\"2857\"\u003e\n\u003ctd data-start=\"2826\" data-end=\"2843\" data-col-size=\"sm\"\u003eHumidity Range\u003c\/td\u003e\n\u003ctd data-start=\"2843\" data-end=\"2857\" data-col-size=\"md\"\u003e25%–98% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2858\" data-end=\"2921\"\u003e\n\u003ctd data-start=\"2858\" data-end=\"2879\" data-col-size=\"sm\"\u003eHumidity Deviation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2879\" data-end=\"2921\"\u003e±3.0% RH (\u0026gt;75% RH); ±5.0% RH (≤75% RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2922\" data-end=\"2992\"\u003e\n\u003ctd data-start=\"2922\" data-end=\"2933\" data-col-size=\"sm\"\u003eWarranty\u003c\/td\u003e\n\u003ctd data-start=\"2933\" data-end=\"2992\" data-col-size=\"md\"\u003e1-year limited warranty with lifetime technical support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2994\" data-end=\"2997\"\u003e\n\u003ch3 data-section-id=\"mgynq\" data-start=\"2999\" data-end=\"3031\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3002\" data-end=\"3031\"\u003eApplications \u0026amp; Industries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3033\" data-end=\"3339\"\u003e\n\u003cli data-section-id=\"11lqhri\" data-start=\"3033\" data-end=\"3076\"\u003eLithium-ion battery reliability testing\u003c\/li\u003e\n\u003cli data-section-id=\"256j6m\" data-start=\"3077\" data-end=\"3124\"\u003eBattery safety and thermal cycling analysis\u003c\/li\u003e\n\u003cli data-section-id=\"at0453\" data-start=\"3125\" data-end=\"3164\"\u003eIn situ battery performance testing\u003c\/li\u003e\n\u003cli data-section-id=\"z88val\" data-start=\"3165\" data-end=\"3204\"\u003eSemiconductor environmental testing\u003c\/li\u003e\n\u003cli data-section-id=\"1metjmu\" data-start=\"3205\" data-end=\"3244\"\u003eSolar cell environmental simulation\u003c\/li\u003e\n\u003cli data-section-id=\"tw6wny\" data-start=\"3245\" data-end=\"3292\"\u003eElectronic component reliability validation\u003c\/li\u003e\n\u003cli data-section-id=\"1c8k1h\" data-start=\"3293\" data-end=\"3339\"\u003eUniversity and industrial R\u0026amp;D laboratories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3341\" data-end=\"3344\"\u003e\n\u003ch3 data-section-id=\"elc90z\" data-start=\"3346\" data-end=\"3356\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3349\" data-end=\"3356\"\u003eFAQ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-section-id=\"v2u6di\" data-start=\"3358\" data-end=\"3415\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3362\" data-end=\"3415\"\u003eWhat temperature range does this chamber support?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3416\" data-end=\"3482\"\u003eThe chamber supports a wide temperature range from -70°C to 150°C.\u003c\/p\u003e\n\u003cp data-section-id=\"tkgqld\" data-start=\"3484\" data-end=\"3540\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3488\" data-end=\"3540\"\u003eCan the chamber be connected to battery cyclers?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3541\" data-end=\"3648\"\u003eYes, predrilled cable ports allow direct integration with battery testing systems for in situ measurements.\u003c\/p\u003e\n\u003cp data-section-id=\"1m7yh9a\" data-start=\"3650\" data-end=\"3700\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3654\" data-end=\"3700\"\u003eDoes the chamber support humidity control?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3701\" data-end=\"3750\"\u003eYes, the humidity control range is 25% to 98% RH.\u003c\/p\u003e\n\u003cp data-section-id=\"quu1j6\" data-start=\"3752\" data-end=\"3816\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3756\" data-end=\"3816\"\u003eWhat types of products can be tested inside the chamber?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3817\" data-end=\"3953\"\u003eIt is suitable for batteries, electronic devices, semiconductors, solar cells, and other environmental reliability testing applications.\u003c\/p\u003e\n\u003cp data-section-id=\"1nf2vtf\" data-start=\"3955\" data-end=\"3998\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3959\" data-end=\"3998\"\u003eIs custom chamber volume available?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3999\" data-end=\"4069\"\u003eYes, chamber capacities from 150L to 1000L are available upon request.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Cell Lab","offers":[{"title":"Default Title","offer_id":52522091118930,"sku":"NW0037","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/6355\/7714\/files\/Neware_WGDW-1000-70_Environmental_Chamber_1000L_-70_C_to_150_C.png?v=1778162507","url":"https:\/\/celllab.co.uk\/products\/neware-wgdw-1000-70-environmental-chamber-1000l-70-c-to-150-c","provider":"Cell Lab Ltd","version":"1.0","type":"link"}