{"product_id":"neware-ct-zwj-4s-t-1u-battery-tester-control-unit-256-channels","title":"Neware CT-ZWJ-4'S-T-1U Battery Tester Control Unit [Middle Machine]","description":"\u003ch2 data-end=\"85\" data-start=\"14\"\u003e\u003cstrong data-end=\"85\" data-start=\"14\"\u003e\u003cmeta charset=\"utf-8\"\u003eNeware CT-ZWJ-4'S-T-1U Battery Tester Control Unit [Middle Machine]\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"264\" data-start=\"87\"\u003eIndustrial battery testing control unit \/ middle machine with Linux-based architecture, TCP\/IP communication, and high-speed multi-channel data management for integrated battery testing systems.\u003c\/p\u003e\n\u003chr data-end=\"269\" data-start=\"266\"\u003e\n\u003ch3 data-end=\"297\" data-start=\"271\" data-section-id=\"1sctfkl\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"297\" data-start=\"274\"\u003eGeneral Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"730\" data-start=\"299\"\u003eThe \u003cmeta charset=\"utf-8\"\u003eNeware\u003cstrong data-end=\"359\" data-start=\"303\"\u003e CT-ZWJ-4'S-T-1U Battery Tester Control Unit\u003c\/strong\u003e \/ Middle Machine is a professional industrial-grade communication and control platform designed for advanced battery testing systems and integrated laboratory automation environments. Engineered for high-channel battery cycler management, the unit provides stable data communication, real-time monitoring, and intelligent testing coordination across large-scale battery testing networks.\u003c\/p\u003e\n\u003cp data-end=\"1070\" data-start=\"732\"\u003eBuilt with an ARM9 processor and Linux-based core architecture, the system supports high-speed TCP\/IP communication with up to \u003cstrong data-end=\"894\" data-start=\"859\"\u003e256 main and auxiliary channels\u003c\/strong\u003e. The platform enables real-time equipment monitoring, automated charge-discharge process control, and intelligent protection logic for continuous battery testing applications.\u003c\/p\u003e\n\u003cp data-end=\"1433\" data-start=\"1072\"\u003eThe control unit supports offline operation protection and automatic test-state recovery after power interruption, ensuring uninterrupted battery testing workflows. It can also integrate with third-party laboratory devices including temperature chambers, chillers, pressure modules, PLC systems, and height measurement systems through communication integration.\u003c\/p\u003e\n\u003cp data-end=\"1760\" data-start=\"1435\"\u003eWith a compact 1U rack-mounted design, RJ45 Ethernet communication, and LCD interface, the CT-ZWJ-4'S-T-1U is suitable for battery R\u0026amp;D laboratories, pilot production lines, and industrial battery testing systems requiring scalable multi-channel management and automated data acquisition.\u003c\/p\u003e\n\u003chr data-end=\"1765\" data-start=\"1762\"\u003e\n\u003ch3 data-end=\"1786\" data-start=\"1767\" data-section-id=\"1j5qwet\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"1786\" data-start=\"1770\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"1897\" data-start=\"1788\"\u003e\u003cstrong data-end=\"1819\" data-start=\"1788\"\u003eSupports Up to 256 Channels\u003c\/strong\u003e\u003cbr data-end=\"1822\" data-start=\"1819\"\u003eControls and manages up to 256 main and auxiliary battery testing channels.\u003c\/p\u003e\n\u003cp data-end=\"2040\" data-start=\"1899\"\u003e\u003cstrong data-end=\"1946\" data-start=\"1899\"\u003eLinux-Based Industrial Control Architecture\u003c\/strong\u003e\u003cbr data-end=\"1949\" data-start=\"1946\"\u003eARM9 processor with Linux core for stable long-term operation and reliable data management.\u003c\/p\u003e\n\u003cp data-end=\"2161\" data-start=\"2042\"\u003e\u003cstrong data-end=\"2077\" data-start=\"2042\"\u003eHigh-Speed TCP\/IP Communication\u003c\/strong\u003e\u003cbr data-end=\"2080\" data-start=\"2077\"\u003eRJ45 Ethernet interface with 100M communication rate for real-time data transfer.\u003c\/p\u003e\n\u003cp data-end=\"2316\" data-start=\"2163\"\u003e\u003cstrong data-end=\"2205\" data-start=\"2163\"\u003ePower-Off Recovery and Offline Testing\u003c\/strong\u003e\u003cbr data-end=\"2208\" data-start=\"2205\"\u003eAutomatically restores testing status after power interruption and supports uninterrupted offline operation.\u003c\/p\u003e\n\u003cp data-end=\"2463\" data-start=\"2318\"\u003e\u003cstrong data-end=\"2352\" data-start=\"2318\"\u003eThird-Party Device Integration\u003c\/strong\u003e\u003cbr data-end=\"2355\" data-start=\"2352\"\u003eCompatible with temperature chambers, chillers, PLC systems, pressure modules, and other external equipment.\u003c\/p\u003e\n\u003chr data-end=\"2468\" data-start=\"2465\"\u003e\n\u003ch3 data-end=\"2491\" data-start=\"2470\" data-section-id=\"q11yyz\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"2491\" data-start=\"2473\"\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"3205\" data-start=\"2493\"\u003e\n\u003cthead data-end=\"2522\" data-start=\"2493\"\u003e\n\u003ctr data-end=\"2522\" data-start=\"2493\"\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"2505\" data-start=\"2493\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" data-col-size=\"sm\" data-end=\"2522\" data-start=\"2505\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"3205\" data-start=\"2533\"\u003e\n\u003ctr data-end=\"2560\" data-start=\"2533\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2541\" data-start=\"2533\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2560\" data-start=\"2541\"\u003eCT-ZWJ-4'S-T-1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2607\" data-start=\"2561\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2576\" data-start=\"2561\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-end=\"2607\" data-start=\"2576\" data-col-size=\"sm\"\u003eBattery Tester Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2646\" data-start=\"2608\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2623\" data-start=\"2608\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2646\" data-start=\"2623\"\u003eAC 220V ±10% \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2669\" data-start=\"2647\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2661\" data-start=\"2647\"\u003eInput Power\u003c\/td\u003e\n\u003ctd data-end=\"2669\" data-start=\"2661\" data-col-size=\"sm\"\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2691\" data-start=\"2670\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2683\" data-start=\"2670\"\u003eData Cache\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2691\" data-start=\"2683\"\u003e1 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2734\" data-start=\"2692\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2713\" data-start=\"2692\"\u003eSampling Frequency\u003c\/td\u003e\n\u003ctd data-end=\"2734\" data-start=\"2713\" data-col-size=\"sm\"\u003eMax. 100Hz (10ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2762\" data-start=\"2735\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2749\" data-start=\"2735\"\u003eClock Error\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2762\" data-start=\"2749\"\u003e1 s \/ Day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2777\" data-start=\"2763\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2769\" data-start=\"2763\"\u003eCPU\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2777\" data-start=\"2769\"\u003eARM9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2808\" data-start=\"2778\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2794\" data-start=\"2778\"\u003eSystem Kernel\u003c\/td\u003e\n\u003ctd data-end=\"2808\" data-start=\"2794\" data-col-size=\"sm\"\u003eLinux Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2826\" data-start=\"2809\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2819\" data-start=\"2809\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-end=\"2826\" data-start=\"2819\" data-col-size=\"sm\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2861\" data-start=\"2827\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2853\" data-start=\"2827\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd data-end=\"2861\" data-start=\"2853\" data-col-size=\"sm\"\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2893\" data-start=\"2862\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2883\" data-start=\"2862\"\u003eCommunication Mode\u003c\/td\u003e\n\u003ctd data-end=\"2893\" data-start=\"2883\" data-col-size=\"sm\"\u003eTCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2923\" data-start=\"2894\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2915\" data-start=\"2894\"\u003eCommunication Rate\u003c\/td\u003e\n\u003ctd data-end=\"2923\" data-start=\"2915\" data-col-size=\"sm\"\u003e100M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2951\" data-start=\"2924\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2943\" data-start=\"2924\"\u003eProtection Level\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2951\" data-start=\"2943\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2988\" data-start=\"2952\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2981\" data-start=\"2952\"\u003eMaximum Supported Channels\u003c\/td\u003e\n\u003ctd data-end=\"2988\" data-start=\"2981\" data-col-size=\"sm\"\u003e256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3025\" data-start=\"2989\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3013\" data-start=\"2989\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3025\" data-start=\"3013\"\u003e0°C–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3062\" data-start=\"3026\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3048\" data-start=\"3026\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-end=\"3062\" data-start=\"3048\" data-col-size=\"sm\"\u003e-10°C–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3112\" data-start=\"3063\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3084\" data-start=\"3063\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd data-end=\"3112\" data-start=\"3084\" data-col-size=\"sm\"\u003e≤70% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3160\" data-start=\"3113\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3132\" data-start=\"3113\"\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd data-end=\"3160\" data-start=\"3132\" data-col-size=\"sm\"\u003e≤80% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3205\" data-start=\"3161\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3174\" data-start=\"3161\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3205\" data-start=\"3174\"\u003e482 × 170 × 50 mm (1U, 19\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp class=\"s16 bolder\" style=\"text-align: left;\"\u003e\u003cmeta charset=\"utf-8\"\u003eTechnical Specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"text-decoration: underline; color: rgb(15, 105, 240);\"\u003e\u003cstrong\u003e\u003cem\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0977\/6355\/7714\/files\/75fa4ddcc3e4944.pdf?v=1779812971\" style=\"color: rgb(15, 105, 240); text-decoration: underline;\" rel=\"noopener\" target=\"_blank\"\u003eClick here\u003c\/a\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"3210\" data-start=\"3207\"\u003e\n\u003ch3 data-end=\"3244\" data-start=\"3212\" data-section-id=\"mgynq\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3244\" data-start=\"3215\"\u003eApplications \u0026amp; Industries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-end=\"3523\" data-start=\"3246\"\u003e\n\u003cli data-end=\"3287\" data-start=\"3246\" data-section-id=\"t75i2q\"\u003eMulti-channel battery testing systems\u003c\/li\u003e\n\u003cli data-end=\"3331\" data-start=\"3288\" data-section-id=\"1toc7o4\"\u003eBattery cycler communication management\u003c\/li\u003e\n\u003cli data-end=\"3360\" data-start=\"3332\" data-section-id=\"kvjpm8\"\u003eBattery R\u0026amp;D laboratories\u003c\/li\u003e\n\u003cli data-end=\"3395\" data-start=\"3361\" data-section-id=\"8jznp1\"\u003ePilot battery production lines\u003c\/li\u003e\n\u003cli data-end=\"3438\" data-start=\"3396\" data-section-id=\"sijyar\"\u003eAutomated battery testing environments\u003c\/li\u003e\n\u003cli data-end=\"3476\" data-start=\"3439\" data-section-id=\"1jbf3i4\"\u003eEnvironmental chamber integration\u003c\/li\u003e\n\u003cli data-end=\"3523\" data-start=\"3477\" data-section-id=\"whj1yd\"\u003eIndustrial battery testing control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3528\" data-start=\"3525\"\u003e\n\u003ch3 data-end=\"3540\" data-start=\"3530\" data-section-id=\"elc90z\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3540\" data-start=\"3533\"\u003eFAQ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"3599\" data-start=\"3542\" data-section-id=\"qr0898\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3599\" data-start=\"3546\"\u003eWhat is the maximum number of channels supported?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3664\" data-start=\"3600\"\u003eThe control unit supports up to 256 main and auxiliary channels.\u003c\/p\u003e\n\u003cp data-end=\"3714\" data-start=\"3666\" data-section-id=\"zg6000\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3714\" data-start=\"3670\"\u003eDoes the system support offline testing?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3836\" data-start=\"3715\"\u003eYes, the unit supports offline operation to ensure testing continues even if upper computer communication is interrupted.\u003c\/p\u003e\n\u003cp data-end=\"3895\" data-start=\"3838\" data-section-id=\"1imco8c\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3895\" data-start=\"3842\"\u003eCan the control unit recover after power failure?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3982\" data-start=\"3896\"\u003eYes, it supports automatic power-off recovery and restores the previous testing state.\u003c\/p\u003e\n\u003cp data-end=\"4041\" data-start=\"3984\" data-section-id=\"hr1m50\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"4041\" data-start=\"3988\"\u003eWhat communication interface does the system use?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"4107\" data-start=\"4042\"\u003eThe system uses RJ45 Ethernet communication with TCP\/IP protocol.\u003c\/p\u003e\n\u003cp data-end=\"4175\" data-start=\"4109\" data-section-id=\"h6ckae\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"4175\" data-start=\"4113\"\u003eCan the control unit integrate with third-party equipment?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"4304\" data-start=\"4176\"\u003eYes, it supports integration with temperature chambers, chillers, PLC systems, pressure modules, and other laboratory equipment.\u003c\/p\u003e","brand":"Cell Lab","offers":[{"title":"Default Title","offer_id":53576052932946,"sku":"NW0049","price":325.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/6355\/7714\/files\/Neware__CT-ZWJ-4_S-T-1U_Battery_Tester_Control_Unit_256_Channels.jpg?v=1779814404","url":"https:\/\/celllab.co.uk\/products\/neware-ct-zwj-4s-t-1u-battery-tester-control-unit-256-channels","provider":"Cell Lab Ltd","version":"1.0","type":"link"}