{"product_id":"neware-ct-4008t-5v6a-battery-tester-8ch-5v-6a","title":"Neware CT-4008T-5V6A Battery Tester [8Ch, 5V 6A]","description":"\u003ch2 data-end=\"66\" data-start=\"14\"\u003e\u003cstrong data-end=\"66\" data-start=\"14\"\u003eNeware CT-4008T-5V6A Battery Tester [8Ch, 5V 6A]\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"205\" data-start=\"68\"\u003eHigh-precision multi-range battery testing system for cylindrical cells, pouch cells, and advanced electrochemical research applications.\u003c\/p\u003e\n\u003chr data-end=\"210\" data-start=\"207\"\u003e\n\u003ch3 data-end=\"238\" data-start=\"212\" data-section-id=\"1sctfkl\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"238\" data-start=\"215\"\u003eGeneral Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"633\" data-start=\"240\"\u003eThe \u003cstrong data-end=\"283\" data-start=\"244\"\u003eNeware CT-4008T-5V6A Battery Tester\u003c\/strong\u003e is a high-precision multi-range battery testing system designed for lithium-ion battery research, electrochemical analysis, and laboratory-scale battery development. As part of the widely adopted CT-4000 series, the system combines high accuracy, rapid data acquisition, and flexible current range control for demanding battery testing applications.\u003c\/p\u003e\n\u003cp data-end=\"945\" data-start=\"635\"\u003eEquipped with 8 independent testing channels, the system supports a voltage range from 25mV to 5V and programmable multi-range current control up to 6A. With ±0.05% FS voltage and current accuracy, it enables highly stable and repeatable testing for cylindrical cells, pouch cells, and electrochemical systems.\u003c\/p\u003e\n\u003cp data-end=\"1225\" data-start=\"947\"\u003eThe CT-4008T platform supports DCIR analysis, dQ\/dV analysis, pulse testing, cycle life testing, and three-electrode system testing. Due to its fast data acquisition capability and stable low-current control, it is also suitable for supercapacitor and EDLC testing applications.\u003c\/p\u003e\n\u003cp data-end=\"1445\" data-start=\"1227\"\u003eThe system includes a main testing unit and a middle machine communication controller. One middle machine can manage up to 10 main testing units, enabling scalable laboratory expansion and centralised software control.\u003c\/p\u003e\n\u003chr data-end=\"1450\" data-start=\"1447\"\u003e\n\u003ch3 data-end=\"1471\" data-start=\"1452\" data-section-id=\"1j5qwet\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"1471\" data-start=\"1455\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"1619\" data-start=\"1473\"\u003e\u003cstrong data-end=\"1517\" data-start=\"1473\"\u003eMulti-Range Current Control Architecture\u003c\/strong\u003e\u003cbr data-end=\"1520\" data-start=\"1517\"\u003eThree programmable current ranges: 0.5mA–0.1A, 0.1A–3A, and 3A–6A for flexible testing performance.\u003c\/p\u003e\n\u003cp data-end=\"1743\" data-start=\"1621\"\u003e\u003cstrong data-end=\"1658\" data-start=\"1621\"\u003eHigh Precision Measurement System\u003c\/strong\u003e\u003cbr data-end=\"1661\" data-start=\"1658\"\u003eVoltage and current accuracy ±0.05% FS for stable and repeatable battery analysis.\u003c\/p\u003e\n\u003cp data-end=\"1883\" data-start=\"1745\"\u003e\u003cstrong data-end=\"1791\" data-start=\"1745\"\u003eAdvanced Electrochemical Testing Functions\u003c\/strong\u003e\u003cbr data-end=\"1794\" data-start=\"1791\"\u003eSupports DCIR testing, dQ\/dV analysis, pulse testing, and three-electrode system testing.\u003c\/p\u003e\n\u003cp data-end=\"2011\" data-start=\"1885\"\u003e\u003cstrong data-end=\"1922\" data-start=\"1885\"\u003eFast Dynamic Response Performance\u003c\/strong\u003e\u003cbr data-end=\"1925\" data-start=\"1922\"\u003eRapid current response with minimum pulse width of 500 ms for dynamic battery testing.\u003c\/p\u003e\n\u003cp data-end=\"2141\" data-start=\"2013\"\u003e\u003cstrong data-end=\"2048\" data-start=\"2013\"\u003eScalable Laboratory Integration\u003c\/strong\u003e\u003cbr data-end=\"2051\" data-start=\"2048\"\u003eOne middle machine can control up to 10 testing units for efficient laboratory deployment.\u003c\/p\u003e\n\u003chr data-end=\"2146\" data-start=\"2143\"\u003e\n\u003ch3 data-end=\"2169\" data-start=\"2148\" data-section-id=\"q11yyz\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"2169\" data-start=\"2151\"\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"2971\" data-start=\"2171\"\u003e\n\u003cthead data-end=\"2200\" data-start=\"2171\"\u003e\n\u003ctr data-end=\"2200\" data-start=\"2171\"\u003e\n\u003cth class=\"\" data-col-size=\"sm\" data-end=\"2183\" data-start=\"2171\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\" data-col-size=\"md\" data-end=\"2200\" data-start=\"2183\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"2971\" data-start=\"2211\"\u003e\n\u003ctr data-end=\"2236\" data-start=\"2211\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2218\" data-start=\"2211\"\u003eSKU#\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2236\" data-start=\"2218\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eNW0027 – 110V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2258\" data-start=\"2237\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2240\" data-start=\"2237\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2258\" data-start=\"2240\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eNW0028 – 220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2305\" data-start=\"2259\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2262\" data-start=\"2259\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2305\" data-start=\"2262\"\u003eNW0029 – 110V, without middle machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2352\" data-start=\"2306\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2309\" data-start=\"2306\"\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2352\" data-start=\"2309\"\u003eNW0030 – 220V, without middle machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2378\" data-start=\"2353\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2361\" data-start=\"2353\"\u003eModel\u003c\/td\u003e\n\u003ctd data-end=\"2378\" data-start=\"2361\" data-col-size=\"md\"\u003eCT-4008T-5V6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2407\" data-start=\"2379\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2390\" data-start=\"2379\"\u003eChannels\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2407\" data-start=\"2390\"\u003e8 independent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2452\" data-start=\"2408\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2423\" data-start=\"2408\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-end=\"2452\" data-start=\"2423\" data-col-size=\"md\"\u003eAC 220V \/ 110V ±10%, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2482\" data-start=\"2453\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2473\" data-start=\"2453\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-end=\"2482\" data-start=\"2473\" data-col-size=\"md\"\u003e425 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2510\" data-start=\"2483\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2499\" data-start=\"2483\"\u003eVoltage Range\u003c\/td\u003e\n\u003ctd data-end=\"2510\" data-start=\"2499\" data-col-size=\"md\"\u003e25mV–5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2543\" data-start=\"2511\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2530\" data-start=\"2511\"\u003eVoltage Accuracy\u003c\/td\u003e\n\u003ctd data-end=\"2543\" data-start=\"2530\" data-col-size=\"md\"\u003e±0.05% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2577\" data-start=\"2544\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2564\" data-start=\"2544\"\u003eVoltage Stability\u003c\/td\u003e\n\u003ctd data-end=\"2577\" data-start=\"2564\" data-col-size=\"md\"\u003e±0.05% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2648\" data-start=\"2578\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2594\" data-start=\"2578\"\u003eCurrent Range\u003c\/td\u003e\n\u003ctd data-end=\"2648\" data-start=\"2594\" data-col-size=\"md\"\u003eRange1: 0.5mA–0.1A; Range2: 0.1A–3A; Range3: 3A–6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2681\" data-start=\"2649\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2668\" data-start=\"2649\"\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd data-end=\"2681\" data-start=\"2668\" data-col-size=\"md\"\u003e±0.05% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2709\" data-start=\"2682\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2699\" data-start=\"2682\"\u003eMaximum Cycles\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2709\" data-start=\"2699\"\u003e65,535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2742\" data-start=\"2710\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2732\" data-start=\"2710\"\u003eMinimum Pulse Width\u003c\/td\u003e\n\u003ctd data-end=\"2742\" data-start=\"2732\" data-col-size=\"md\"\u003e500 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2778\" data-start=\"2743\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2756\" data-start=\"2743\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2778\" data-start=\"2756\"\u003e483 × 404 × 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2797\" data-start=\"2779\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2788\" data-start=\"2779\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2797\" data-start=\"2788\"\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2836\" data-start=\"2798\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2814\" data-start=\"2798\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-end=\"2836\" data-start=\"2814\" data-col-size=\"md\"\u003eVia middle machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2900\" data-start=\"2837\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2851\" data-start=\"2837\"\u003eClamp Types\u003c\/td\u003e\n\u003ctd data-end=\"2900\" data-start=\"2851\" data-col-size=\"md\"\u003eCoin \/ Cylindrical \/ Polymer clamps available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2971\" data-start=\"2901\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2912\" data-start=\"2901\"\u003eWarranty\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2971\" data-start=\"2912\"\u003e1-year limited warranty with lifetime technical support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"2976\" data-start=\"2973\"\u003e\n\u003ch3 data-end=\"3010\" data-start=\"2978\" data-section-id=\"mgynq\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3010\" data-start=\"2981\"\u003eApplications \u0026amp; Industries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-end=\"3298\" data-start=\"3012\"\u003e\n\u003cli data-end=\"3048\" data-start=\"3012\" data-section-id=\"1adjrxx\"\u003eCylindrical cell battery testing\u003c\/li\u003e\n\u003cli data-end=\"3088\" data-start=\"3049\" data-section-id=\"1j7z267\"\u003ePouch cell electrochemical analysis\u003c\/li\u003e\n\u003cli data-end=\"3122\" data-start=\"3089\" data-section-id=\"4ss4th\"\u003eBattery cycle life evaluation\u003c\/li\u003e\n\u003cli data-end=\"3164\" data-start=\"3123\" data-section-id=\"3dqha8\"\u003eDC internal resistance (DCIR) testing\u003c\/li\u003e\n\u003cli data-end=\"3200\" data-start=\"3165\" data-section-id=\"12yf72i\"\u003eSupercapacitor and EDLC testing\u003c\/li\u003e\n\u003cli data-end=\"3249\" data-start=\"3201\" data-section-id=\"105455i\"\u003eUniversity and battery research laboratories\u003c\/li\u003e\n\u003cli data-end=\"3298\" data-start=\"3250\" data-section-id=\"htopyg\"\u003eBattery manufacturing and quality validation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3303\" data-start=\"3300\"\u003e\n\u003ch3 data-end=\"3315\" data-start=\"3305\" data-section-id=\"elc90z\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3315\" data-start=\"3308\"\u003eFAQ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-end=\"3370\" data-start=\"3317\" data-section-id=\"pi2sg3\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3370\" data-start=\"3321\"\u003eWhat types of batteries can this system test?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3479\" data-start=\"3371\"\u003eIt is designed for cylindrical cells, pouch cells, and other rechargeable battery systems within a 5V range.\u003c\/p\u003e\n\u003cp data-end=\"3514\" data-start=\"3481\" data-section-id=\"5z5d5s\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3514\" data-start=\"3485\"\u003eWhat is a middle machine?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3605\" data-start=\"3515\"\u003eThe middle machine acts as the communication interface between the PC and battery cyclers.\u003c\/p\u003e\n\u003cp data-end=\"3663\" data-start=\"3607\" data-section-id=\"1id839g\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3663\" data-start=\"3611\"\u003eHow many cyclers can one middle machine control?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3718\" data-start=\"3664\"\u003eOne middle machine can control up to 10 testing units.\u003c\/p\u003e\n\u003cp data-end=\"3787\" data-start=\"3720\" data-section-id=\"10ffpee\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3787\" data-start=\"3724\"\u003eDoes the system support electrochemical analysis functions?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"3879\" data-start=\"3788\"\u003eYes, it supports DCIR analysis, dQ\/dV analysis, pulse testing, and three-electrode testing.\u003c\/p\u003e\n\u003cp data-end=\"3928\" data-start=\"3881\" data-section-id=\"i9fazu\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-end=\"3928\" data-start=\"3885\"\u003eCan existing middle machines be reused?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-end=\"4043\" data-start=\"3929\"\u003eCompatibility depends on the version of the existing middle machine. Older versions may not support newer cyclers.\u003c\/p\u003e","brand":"Cell Lab","offers":[{"title":"110V","offer_id":52522091348306,"sku":"NW0027","price":2459.0,"currency_code":"GBP","in_stock":true},{"title":"220V","offer_id":52522091381074,"sku":"NW0028","price":2459.0,"currency_code":"GBP","in_stock":true},{"title":"110V without middle machine","offer_id":52522091413842,"sku":"NW0029","price":2299.0,"currency_code":"GBP","in_stock":true},{"title":"220V without middle machine","offer_id":52522091446610,"sku":"NW0030","price":2299.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/6355\/7714\/files\/Neware_CT-4008T-5V6A_Battery_Tester_8Ch_5V_6A.png?v=1778159436","url":"https:\/\/celllab.co.uk\/products\/neware-ct-4008t-5v6a-battery-tester-8ch-5v-6a","provider":"Cell Lab Ltd","version":"1.0","type":"link"}