{"product_id":"neware-ce-6004n-120v100a-h-battery-module-testing-system","title":"Neware CE-6004n-120V100A-H Battery Module Testing System","description":"\u003ch2\u003eNeware CE-6004n-120V100A-H Battery Module Testing System\u003c\/h2\u003e\n\u003cp data-end=\"402\" data-start=\"278\"\u003eHigh-power regenerative battery cycler for module and battery pack testing with high precision control and dynamic response.\u003c\/p\u003e\n\u003chr data-end=\"407\" data-start=\"404\"\u003e\n\u003ch3 data-end=\"435\" data-start=\"409\" data-section-id=\"1sctfkl\"\u003eGeneral Description\u003c\/h3\u003e\n\u003cp data-end=\"870\" data-start=\"437\"\u003eThe Neware\u003cstrong data-end=\"503\" data-start=\"441\"\u003e CE-6004n-120V100A-H Battery Module Testing System\u003c\/strong\u003e is a high-power battery charge–discharge platform designed for battery module and battery pack testing in advanced energy storage and electric vehicle applications. Built on the CE-6000 high-power architecture, the system provides high dynamic response speed, excellent measurement accuracy, and stable long-term operation for demanding battery testing environments.\u003c\/p\u003e\n\u003cp data-end=\"1244\" data-start=\"872\"\u003eThe system supports a wide voltage range up to \u003cstrong data-end=\"927\" data-start=\"919\"\u003e120V\u003c\/strong\u003e and current up to \u003cstrong data-end=\"954\" data-start=\"946\"\u003e100A\u003c\/strong\u003e, delivering up to \u003cstrong data-end=\"1006\" data-start=\"973\"\u003e12kW output power per channel\u003c\/strong\u003e. With four independent channels and a total system output power of \u003cstrong data-end=\"1082\" data-start=\"1074\"\u003e48kW\u003c\/strong\u003e, it enables efficient testing of high-capacity battery modules and packs for cycle life evaluation, performance validation, and dynamic driving simulation tests.\u003c\/p\u003e\n\u003cp data-end=\"1667\" data-start=\"1246\"\u003eThe CE-6000 series adopts a \u003cstrong data-end=\"1309\" data-start=\"1274\"\u003eregenerative power architecture\u003c\/strong\u003e, allowing discharged energy to be reused by other charging channels or fed back to the power grid, significantly improving energy efficiency and reducing operating costs. The system consists of a main testing unit and a communication controller (middle machine), which allows centralised control through computer software and scalable laboratory deployment.\u003c\/p\u003e\n\u003chr data-end=\"1672\" data-start=\"1669\"\u003e\n\u003ch3 data-end=\"1693\" data-start=\"1674\" data-section-id=\"1j5qwet\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"1824\" data-start=\"1695\"\u003e\n\u003cstrong data-end=\"1732\" data-start=\"1695\"\u003eHigh-Power Battery Module Testing\u003c\/strong\u003e\u003cbr data-end=\"1735\" data-start=\"1732\"\u003eSupports up to \u003cstrong data-end=\"1779\" data-start=\"1750\"\u003e120V and 100A per channel\u003c\/strong\u003e, ideal for battery modules and pack testing.\u003c\/li\u003e\n\u003cli data-end=\"1964\" data-start=\"1826\"\u003e\n\u003cstrong data-end=\"1856\" data-start=\"1826\"\u003eHigh Precision Measurement\u003c\/strong\u003e\u003cbr data-end=\"1859\" data-start=\"1856\"\u003eVoltage accuracy \u003cstrong data-end=\"1889\" data-start=\"1876\"\u003e±0.02% FS\u003c\/strong\u003e and current accuracy \u003cstrong data-end=\"1924\" data-start=\"1911\"\u003e±0.05% FS\u003c\/strong\u003e ensure reliable and repeatable results.\u003c\/li\u003e\n\u003cli data-end=\"2121\" data-start=\"1966\"\u003e\n\u003cstrong data-end=\"2000\" data-start=\"1966\"\u003eRegenerative Energy Technology\u003c\/strong\u003e\u003cbr data-end=\"2003\" data-start=\"2000\"\u003eRecovered discharge energy can be reused by other channels or returned to the power grid to reduce energy consumption.\u003c\/li\u003e\n\u003cli data-end=\"2248\" data-start=\"2123\"\u003e\n\u003cstrong data-end=\"2163\" data-start=\"2123\"\u003eFlexible Multi-Channel Configuration\u003c\/strong\u003e\u003cbr data-end=\"2166\" data-start=\"2163\"\u003eFour independent channels enable simultaneous testing of multiple battery modules.\u003c\/li\u003e\n\u003cli data-end=\"2398\" data-start=\"2250\"\u003e\n\u003cstrong data-end=\"2285\" data-start=\"2250\"\u003eAdvanced Battery Test Functions\u003c\/strong\u003e\u003cbr data-end=\"2288\" data-start=\"2285\"\u003eSupports pulse testing, cycle life testing, and driving simulation tests for comprehensive battery evaluation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2403\" data-start=\"2400\"\u003e\n\u003ch3 data-end=\"2426\" data-start=\"2405\" data-section-id=\"q11yyz\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-end=\"3107\" data-start=\"2428\"\u003e\n\u003cthead data-end=\"2457\" data-start=\"2428\"\u003e\n\u003ctr data-end=\"2457\" data-start=\"2428\"\u003e\n\u003cth class=\"\" data-col-size=\"sm\" data-end=\"2440\" data-start=\"2428\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\" data-col-size=\"md\" data-end=\"2457\" data-start=\"2440\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-end=\"3107\" data-start=\"2468\"\u003e\n\u003ctr data-end=\"2499\" data-start=\"2468\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2476\" data-start=\"2468\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2499\" data-start=\"2476\"\u003eCE-6004n-120V100A-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2528\" data-start=\"2500\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2511\" data-start=\"2500\"\u003eChannels\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2528\" data-start=\"2511\"\u003e4 independent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2582\" data-start=\"2529\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2544\" data-start=\"2529\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2582\" data-start=\"2544\"\u003eAC 380V ±15%, 50\/60Hz, three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2608\" data-start=\"2583\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2597\" data-start=\"2583\"\u003eInput Power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2608\" data-start=\"2597\"\u003e56.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2643\" data-start=\"2609\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2625\" data-start=\"2609\"\u003eInput Current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2643\" data-start=\"2625\"\u003e85.8 A \/ phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2672\" data-start=\"2644\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2663\" data-start=\"2644\"\u003eInput Resistance\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2672\" data-start=\"2663\"\u003e≥1 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2691\" data-start=\"2673\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2681\" data-start=\"2673\"\u003eNoise\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2691\" data-start=\"2681\"\u003e≤65 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2747\" data-start=\"2692\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2708\" data-start=\"2692\"\u003eVoltage Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2747\" data-start=\"2708\"\u003eCharge: 0–120 V; Discharge: 3–120 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2780\" data-start=\"2748\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2767\" data-start=\"2748\"\u003eVoltage Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2780\" data-start=\"2767\"\u003e±0.02% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2812\" data-start=\"2781\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2797\" data-start=\"2781\"\u003eCurrent Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2812\" data-start=\"2797\"\u003e0.5 – 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2845\" data-start=\"2813\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2832\" data-start=\"2813\"\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2845\" data-start=\"2832\"\u003e±0.05% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2877\" data-start=\"2846\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2867\" data-start=\"2846\"\u003eCV Cut-off Current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2877\" data-start=\"2867\"\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2914\" data-start=\"2878\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2905\" data-start=\"2878\"\u003eOutput Power per Channel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2914\" data-start=\"2905\"\u003e12 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2945\" data-start=\"2915\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2936\" data-start=\"2915\"\u003eTotal Output Power\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2945\" data-start=\"2936\"\u003e48 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"2982\" data-start=\"2946\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2959\" data-start=\"2946\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"2982\" data-start=\"2959\"\u003e600 × 800 × 1300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3002\" data-start=\"2983\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"2992\" data-start=\"2983\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3002\" data-start=\"2992\"\u003e206 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3036\" data-start=\"3003\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3027\" data-start=\"3003\"\u003eStandard Cable Length\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3036\" data-start=\"3027\"\u003e0.2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-end=\"3107\" data-start=\"3037\"\u003e\n\u003ctd data-col-size=\"sm\" data-end=\"3048\" data-start=\"3037\"\u003eWarranty\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-end=\"3107\" data-start=\"3048\"\u003e1-year limited warranty with lifetime technical support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-end=\"3112\" data-start=\"3109\"\u003e\n\u003ch3 data-end=\"3146\" data-start=\"3114\" data-section-id=\"mgynq\"\u003eApplications \u0026amp; Industries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli data-end=\"3395\" data-start=\"3148\"\u003eBattery module and pack testing\u003cbr data-end=\"3182\" data-start=\"3179\"\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3395\" data-start=\"3148\"\u003eElectric vehicle battery validation\u003cbr data-end=\"3220\" data-start=\"3217\"\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3395\" data-start=\"3148\"\u003eEnergy storage system development\u003cbr data-end=\"3256\" data-start=\"3253\"\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3395\" data-start=\"3148\"\u003eBattery cycle life and durability testing\u003cbr data-end=\"3300\" data-start=\"3297\"\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3395\" data-start=\"3148\"\u003eDriving cycle simulation and performance analysis\u003cbr data-end=\"3352\" data-start=\"3349\"\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3395\" data-start=\"3148\"\u003eBattery manufacturing and quality control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3400\" data-start=\"3397\"\u003e\n\u003ch3 data-end=\"3412\" data-start=\"3402\" data-section-id=\"elc90z\"\u003eFAQ\u003c\/h3\u003e\n\u003cp data-end=\"3617\" data-start=\"3414\"\u003e\u003cstrong data-end=\"3443\" data-start=\"3414\"\u003eWhat is a middle machine?\u003c\/strong\u003e\u003cbr data-end=\"3446\" data-start=\"3443\"\u003eThe middle machine acts as the communication interface between the computer and the battery cyclers. At least one middle machine is required to operate the testing system.\u003c\/p\u003e\n\u003cp data-end=\"3743\" data-start=\"3619\"\u003e\u003cstrong data-end=\"3677\" data-start=\"3619\"\u003eHow many testing units can one middle machine control?\u003c\/strong\u003e\u003cbr data-end=\"3680\" data-start=\"3677\"\u003eOne middle machine can control up to \u003cstrong data-end=\"3742\" data-start=\"3717\"\u003e10 main testing units\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"3882\" data-start=\"3745\"\u003e\u003cstrong data-end=\"3801\" data-start=\"3745\"\u003eIs the middle machine the same for all cycler types?\u003c\/strong\u003e\u003cbr data-end=\"3804\" data-start=\"3801\"\u003eYes. A single type of middle machine can be used with different cycler models.\u003c\/p\u003e","brand":"Cell Lab","offers":[{"title":"4 Channels CE-6004n-120V100A-H","offer_id":52522081812818,"sku":"NW0008","price":19149.0,"currency_code":"GBP","in_stock":true},{"title":"8 Channels CE-6008n-120V100A-H","offer_id":52522081845586,"sku":"NW0009","price":28899.0,"currency_code":"GBP","in_stock":true},{"title":"12 Channels CE-6012n-120V100A-H","offer_id":52522081878354,"sku":"NW0010","price":45389.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/6355\/7714\/files\/Neware_CE-6004n-120V100A-H_Battery_Module_Testing_System.png?v=1773424190","url":"https:\/\/celllab.co.uk\/products\/neware-ce-6004n-120v100a-h-battery-module-testing-system","provider":"Cell Lab Ltd","version":"1.0","type":"link"}