{"product_id":"neware-ce-6000-battery-module-pack-testing-system","title":"Neware CE-6000 Battery Module \u0026 Pack Testing System","description":"\u003ch2 data-start=\"14\" data-end=\"69\"\u003e\u003cstrong data-start=\"14\" data-end=\"69\"\u003eNeware CE-6000 Battery Module \u0026amp; Pack Testing System\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"71\" data-end=\"198\"\u003eRegenerative high-power battery testing platform for cells, modules, packs, BMS validation, and EV energy storage applications.\u003c\/p\u003e\n\u003chr data-start=\"200\" data-end=\"203\"\u003e\n\u003ch3 data-section-id=\"1sctfkl\" data-start=\"205\" data-end=\"231\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"208\" data-end=\"231\"\u003eGeneral Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"233\" data-end=\"759\"\u003eThe \u003cstrong data-start=\"237\" data-end=\"278\"\u003eNeware CE-6000 Battery Testing System\u003c\/strong\u003e is Neware’s flagship high-power regenerative testing platform developed for comprehensive evaluation of battery cells, modules, battery packs, energy storage systems, and electric vehicle batteries. Designed for advanced battery R\u0026amp;D, pilot production, validation laboratories, and manufacturing environments, the CE-6000 series combines ultra-high precision measurement, high-power energy recovery technology, and flexible system scalability. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"761\" data-end=\"1103\"\u003eThe CE-6000 platform supports a wide range of voltage and current configurations, from low-voltage cell testing to ultra-high-voltage battery cluster testing up to \u003cstrong data-start=\"925\" data-end=\"934\"\u003e3000V\u003c\/strong\u003e, making it suitable for applications ranging from individual lithium-ion cells to large-scale energy storage and EV battery packs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1105\" data-end=\"1580\"\u003eFeaturing regenerative power technology, the system recovers discharge energy and returns it to the grid or redistributes it to charging channels, significantly reducing power consumption and operating costs during long-term testing. The platform supports pulse testing, DCIR analysis, driving cycle simulation, BMS communication, EOL testing, and environmental chamber integration for complete battery performance and safety validation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1582\" data-end=\"1874\"\u003eBuilt on Neware's high-speed control architecture, the CE-6000 delivers fast dynamic response, multi-channel scalability, high-accuracy measurement, and comprehensive automation capabilities for next-generation battery development and production testing. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"1876\" data-end=\"1879\"\u003e\n\u003ch3 data-section-id=\"1j5qwet\" data-start=\"1881\" data-end=\"1900\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1884\" data-end=\"1900\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1902\" data-end=\"2083\"\u003e\u003cstrong data-start=\"1902\" data-end=\"1949\"\u003eComprehensive Cell-to-Pack Testing Platform\u003c\/strong\u003e\u003cbr data-start=\"1949\" data-end=\"1952\"\u003eSupports battery cell, module, pack, battery cluster, PCS, and energy storage system testing. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2085\" data-end=\"2271\"\u003e\u003cstrong data-start=\"2085\" data-end=\"2128\"\u003eRegenerative Energy Recovery Technology\u003c\/strong\u003e\u003cbr data-start=\"2128\" data-end=\"2131\"\u003eDischarge energy can be reused by charging channels or returned to the grid, reducing operating costs. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2273\" data-end=\"2445\"\u003e\u003cstrong data-start=\"2273\" data-end=\"2304\"\u003eUltra-Wide Voltage Coverage\u003c\/strong\u003e\u003cbr data-start=\"2304\" data-end=\"2307\"\u003eAvailable configurations from 5V cell testing systems up to 3000V battery cluster testing platforms. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2447\" data-end=\"2626\"\u003e\u003cstrong data-start=\"2447\" data-end=\"2488\"\u003eAdvanced Battery Validation Functions\u003c\/strong\u003e\u003cbr data-start=\"2488\" data-end=\"2491\"\u003eSupports pulse testing, DCIR analysis, driving cycle simulation, EOL testing, and BMS validation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2628\" data-end=\"2806\"\u003e\u003cstrong data-start=\"2628\" data-end=\"2664\"\u003eFlexible Multi-Channel Expansion\u003c\/strong\u003e\u003cbr data-start=\"2664\" data-end=\"2667\"\u003eModular architecture allows scalable channel configurations for research and production environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2808\" data-end=\"2811\"\u003e\n\u003ch3 data-section-id=\"q11yyz\" data-start=\"2813\" data-end=\"2834\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2816\" data-end=\"2834\"\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2836\" data-end=\"4169\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2836\" data-end=\"2865\"\u003e\n\u003ctr data-start=\"2836\" data-end=\"2865\"\u003e\n\u003cth data-start=\"2836\" data-end=\"2848\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2848\" data-end=\"2865\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2876\" data-end=\"4169\"\u003e\n\u003ctr data-start=\"2876\" data-end=\"2896\"\u003e\n\u003ctd data-start=\"2876\" data-end=\"2885\" data-col-size=\"sm\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-start=\"2885\" data-end=\"2896\" data-col-size=\"md\"\u003eCE-6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2897\" data-end=\"2951\"\u003e\n\u003ctd data-start=\"2897\" data-end=\"2912\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2912\" data-end=\"2951\"\u003eRegenerative Battery Testing System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2952\" data-end=\"3023\"\u003e\n\u003ctd data-start=\"2952\" data-end=\"2967\" data-col-size=\"sm\"\u003eApplications\u003c\/td\u003e\n\u003ctd data-start=\"2967\" data-end=\"3023\" data-col-size=\"md\"\u003eCell, Module, Pack, Cluster, ESS, EV Battery Testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3024\" data-end=\"3062\"\u003e\n\u003ctd data-start=\"3024\" data-end=\"3048\" data-col-size=\"sm\"\u003eVoltage Range Options\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3048\" data-end=\"3062\"\u003e5V – 3000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3063\" data-end=\"3131\"\u003e\n\u003ctd data-start=\"3063\" data-end=\"3087\" data-col-size=\"sm\"\u003eCurrent Range Options\u003c\/td\u003e\n\u003ctd data-start=\"3087\" data-end=\"3131\" data-col-size=\"md\"\u003e20A – 2400A (depending on configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3132\" data-end=\"3170\"\u003e\n\u003ctd data-start=\"3132\" data-end=\"3151\" data-col-size=\"sm\"\u003eVoltage Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3151\" data-end=\"3170\" data-col-size=\"md\"\u003eUp to ±0.02% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3171\" data-end=\"3260\"\u003e\n\u003ctd data-start=\"3171\" data-end=\"3190\" data-col-size=\"sm\"\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"3190\" data-end=\"3260\" data-col-size=\"md\"\u003eUp to ±0.02% FS (cell systems) \/ ±0.05% FS (module \u0026amp; pack systems)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3261\" data-end=\"3299\"\u003e\n\u003ctd data-start=\"3261\" data-end=\"3274\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3274\" data-end=\"3299\"\u003e24-bit AD Acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3300\" data-end=\"3352\"\u003e\n\u003ctd data-start=\"3300\" data-end=\"3316\" data-col-size=\"sm\"\u003eResponse Time\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3316\" data-end=\"3352\"\u003e≤1.5ms to ≤5ms (model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3353\" data-end=\"3397\"\u003e\n\u003ctd data-start=\"3353\" data-end=\"3382\" data-col-size=\"sm\"\u003eData Acquisition Frequency\u003c\/td\u003e\n\u003ctd data-start=\"3382\" data-end=\"3397\" data-col-size=\"md\"\u003eUp to 100Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3398\" data-end=\"3427\"\u003e\n\u003ctd data-start=\"3398\" data-end=\"3414\" data-col-size=\"sm\"\u003ePulse Testing\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3414\" data-end=\"3427\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3428\" data-end=\"3457\"\u003e\n\u003ctd data-start=\"3428\" data-end=\"3444\" data-col-size=\"sm\"\u003eDCIR Analysis\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3444\" data-end=\"3457\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3458\" data-end=\"3498\"\u003e\n\u003ctd data-start=\"3458\" data-end=\"3485\" data-col-size=\"sm\"\u003eDriving Cycle Simulation\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3485\" data-end=\"3498\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3499\" data-end=\"3532\"\u003e\n\u003ctd data-start=\"3499\" data-end=\"3519\" data-col-size=\"sm\"\u003eBMS Communication\u003c\/td\u003e\n\u003ctd data-start=\"3519\" data-end=\"3532\" data-col-size=\"md\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3533\" data-end=\"3569\"\u003e\n\u003ctd data-start=\"3533\" data-end=\"3556\" data-col-size=\"sm\"\u003eDBC Protocol Support\u003c\/td\u003e\n\u003ctd data-start=\"3556\" data-end=\"3569\" data-col-size=\"md\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3570\" data-end=\"3597\"\u003e\n\u003ctd data-start=\"3570\" data-end=\"3584\" data-col-size=\"sm\"\u003eEOL Testing\u003c\/td\u003e\n\u003ctd data-start=\"3584\" data-end=\"3597\" data-col-size=\"md\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3598\" data-end=\"3642\"\u003e\n\u003ctd data-start=\"3598\" data-end=\"3629\" data-col-size=\"sm\"\u003eAuxiliary Voltage Monitoring\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3629\" data-end=\"3642\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3643\" data-end=\"3691\"\u003e\n\u003ctd data-start=\"3643\" data-end=\"3678\" data-col-size=\"sm\"\u003eAuxiliary Temperature Monitoring\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3678\" data-end=\"3691\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3692\" data-end=\"3741\"\u003e\n\u003ctd data-start=\"3692\" data-end=\"3728\" data-col-size=\"sm\"\u003eEnvironmental Chamber Integration\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3728\" data-end=\"3741\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3742\" data-end=\"3784\"\u003e\n\u003ctd data-start=\"3742\" data-end=\"3771\" data-col-size=\"sm\"\u003eEnergy Recovery Efficiency\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3771\" data-end=\"3784\"\u003eUp to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3785\" data-end=\"3823\"\u003e\n\u003ctd data-start=\"3785\" data-end=\"3801\" data-col-size=\"sm\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3801\" data-end=\"3823\"\u003eTCP\/IP, CAN, RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3824\" data-end=\"3844\"\u003e\n\u003ctd data-start=\"3824\" data-end=\"3835\" data-col-size=\"sm\"\u003eDatabase\u003c\/td\u003e\n\u003ctd data-start=\"3835\" data-end=\"3844\" data-col-size=\"md\"\u003eMySQL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3845\" data-end=\"3890\"\u003e\n\u003ctd data-start=\"3845\" data-end=\"3859\" data-col-size=\"sm\"\u003eData Export\u003c\/td\u003e\n\u003ctd data-start=\"3859\" data-end=\"3890\" data-col-size=\"md\"\u003eExcel, TXT, CSV, PDF, Graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3891\" data-end=\"3937\"\u003e\n\u003ctd data-start=\"3891\" data-end=\"3910\" data-col-size=\"sm\"\u003eOperating System\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3910\" data-end=\"3937\"\u003eWindows 10 \/ Windows 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3938\" data-end=\"3993\"\u003e\n\u003ctd data-start=\"3938\" data-end=\"3958\" data-col-size=\"sm\"\u003eChannel Expansion\u003c\/td\u003e\n\u003ctd data-start=\"3958\" data-end=\"3993\" data-col-size=\"md\"\u003eModular expandable architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3994\" data-end=\"4078\"\u003e\n\u003ctd data-start=\"3994\" data-end=\"4014\" data-col-size=\"sm\"\u003eSafety Protection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4014\" data-end=\"4078\"\u003eOver-voltage, over-current, over-temperature, emergency stop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4079\" data-end=\"4169\"\u003e\n\u003ctd data-start=\"4079\" data-end=\"4104\" data-col-size=\"sm\"\u003eApplication Industries\u003c\/td\u003e\n\u003ctd data-start=\"4104\" data-end=\"4169\" data-col-size=\"md\"\u003eEV, ESS, Telecom Storage, Power Tools, E-Bikes, E-Motorcycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"4171\" data-end=\"4174\"\u003e\n\u003ch3 data-section-id=\"mgynq\" data-start=\"4176\" data-end=\"4208\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4179\" data-end=\"4208\"\u003eApplications \u0026amp; Industries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"4210\" data-end=\"4652\"\u003e\n\u003cli data-section-id=\"5vjd8t\" data-start=\"4210\" data-end=\"4250\"\u003eElectric vehicle battery development\u003c\/li\u003e\n\u003cli data-section-id=\"1xqkv1e\" data-start=\"4251\" data-end=\"4288\"\u003eBattery module validation testing\u003c\/li\u003e\n\u003cli data-section-id=\"1y24zqx\" data-start=\"4289\" data-end=\"4330\"\u003eBattery pack charge-discharge testing\u003c\/li\u003e\n\u003cli data-section-id=\"1v9dfvo\" data-start=\"4331\" data-end=\"4373\"\u003eEnergy storage system (ESS) evaluation\u003c\/li\u003e\n\u003cli data-section-id=\"1j3y5ks\" data-start=\"4374\" data-end=\"4408\"\u003eTelecom energy storage testing\u003c\/li\u003e\n\u003cli data-section-id=\"5iiurw\" data-start=\"4409\" data-end=\"4447\"\u003eBattery production quality control\u003c\/li\u003e\n\u003cli data-section-id=\"ros0j9\" data-start=\"4448\" data-end=\"4484\"\u003eBMS development and verification\u003c\/li\u003e\n\u003cli data-section-id=\"3ibwnw\" data-start=\"4485\" data-end=\"4522\"\u003eEnd-of-line (EOL) battery testing\u003c\/li\u003e\n\u003cli data-section-id=\"1ih814h\" data-start=\"4523\" data-end=\"4582\"\u003eUniversity and industrial battery research laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"3sw3lf\" data-start=\"4583\" data-end=\"4652\"\u003eBattery cluster and PCS testing for utility-scale storage systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4654\" data-end=\"4657\"\u003e\n\u003ch3 data-section-id=\"elc90z\" data-start=\"4659\" data-end=\"4669\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4662\" data-end=\"4669\"\u003eFAQ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-section-id=\"u451q3\" data-start=\"4671\" data-end=\"4719\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4675\" data-end=\"4719\"\u003eWhat battery types can the CE-6000 test?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"4720\" data-end=\"4825\"\u003eThe CE-6000 supports battery cells, modules, battery packs, battery clusters, and energy storage systems.\u003c\/p\u003e\n\u003cp data-section-id=\"dwet8d\" data-start=\"4827\" data-end=\"4889\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4831\" data-end=\"4889\"\u003eDoes the CE-6000 support regenerative energy recovery?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"4890\" data-end=\"5050\"\u003eYes. The system can return discharge energy to the grid or reuse it internally, significantly reducing energy consumption. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-section-id=\"1w10vrf\" data-start=\"5052\" data-end=\"5120\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5056\" data-end=\"5120\"\u003eWhat is the maximum voltage available in the CE-6000 series?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"5121\" data-end=\"5253\"\u003eThe platform is available in configurations up to 3000V for battery cluster and PCS testing. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-section-id=\"1h4339g\" data-start=\"5255\" data-end=\"5308\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5259\" data-end=\"5308\"\u003eCan the CE-6000 communicate with BMS systems?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"5309\" data-end=\"5457\"\u003eYes. The platform supports CAN communication, DBC file integration, and comprehensive BMS testing functions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-section-id=\"1qofqeh\" data-start=\"5459\" data-end=\"5521\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5463\" data-end=\"5521\"\u003eCan the CE-6000 integrate with environmental chambers?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"5522\" data-end=\"5704\"\u003eYes. The system supports auxiliary voltage, auxiliary temperature, and environmental chamber integration for multidimensional battery testing. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Cell Lab","offers":[{"title":"Default Title","offer_id":53693318365522,"sku":"NW0060","price":8870.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/6355\/7714\/files\/Neware_CE-6000_Battery_Module_Pack_Testing_System.jpg?v=1781022519","url":"https:\/\/celllab.co.uk\/products\/neware-ce-6000-battery-module-pack-testing-system","provider":"Cell Lab Ltd","version":"1.0","type":"link"}