{"product_id":"neware-ca-4032n-1u-t-tc-auxiliary-temperature-unit-32ch","title":"Neware CA-4032n-1U-T-TC Auxiliary Temperature Unit [32Ch]","description":"\u003ch2 data-start=\"14\" data-end=\"75\"\u003e\u003cstrong data-start=\"14\" data-end=\"75\"\u003eNeware CA-4032n-1U-T-TC Auxiliary Temperature Unit [32Ch]\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"77\" data-end=\"210\"\u003e32-channel thermocouple auxiliary temperature acquisition unit for battery thermal monitoring and integrated battery testing systems.\u003c\/p\u003e\n\u003chr data-start=\"212\" data-end=\"215\"\u003e\n\u003ch3 data-section-id=\"1sctfkl\" data-start=\"217\" data-end=\"243\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"220\" data-end=\"243\"\u003eGeneral Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"245\" data-end=\"647\"\u003eThe \u003cstrong data-start=\"249\" data-end=\"303\"\u003eNeware CA-4032n-1U-T-TC Auxiliary Temperature Unit\u003c\/strong\u003e is a professional multi-channel temperature acquisition module designed for advanced battery thermal monitoring and safety validation applications. Developed for integration with Neware battery charge-discharge systems, the unit enables synchronised temperature monitoring during electrochemical testing and environmental evaluation workflows.\u003c\/p\u003e\n\u003cp data-start=\"649\" data-end=\"1071\"\u003eThis configuration supports \u003cstrong data-start=\"677\" data-end=\"728\"\u003e32 independent temperature acquisition channels\u003c\/strong\u003e using thermocouple sensors, providing high-density thermal monitoring for battery cells, battery modules, and large-scale battery testing systems. The system supports a wide temperature measurement range from \u003cstrong data-start=\"938\" data-end=\"957\"\u003e-200°C to 260°C\u003c\/strong\u003e, making it suitable for high-temperature testing, thermal runaway studies, and environmental chamber integration.\u003c\/p\u003e\n\u003cp data-start=\"1073\" data-end=\"1440\"\u003eWith a sampling frequency of \u003cstrong data-start=\"1102\" data-end=\"1118\"\u003e10Hz (100ms)\u003c\/strong\u003e and temperature resolution of \u003cstrong data-start=\"1149\" data-end=\"1158\"\u003e0.1°C\u003c\/strong\u003e, the platform delivers stable real-time thermal acquisition for laboratory and industrial battery testing environments. Auxiliary temperature channels can be flexibly mapped to any primary channel under the same middle machine, enabling scalable battery testing system integration.\u003c\/p\u003e\n\u003cp data-start=\"1442\" data-end=\"1731\"\u003eBuilt with RS485 communication architecture and industrial-grade protection design, the CA-4032n-1U-T-TC is suitable for lithium-ion battery R\u0026amp;D, energy storage testing, environmental simulation systems, and industrial battery validation applications.\u003c\/p\u003e\n\u003chr data-start=\"1733\" data-end=\"1736\"\u003e\n\u003ch3 data-section-id=\"1j5qwet\" data-start=\"1738\" data-end=\"1757\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1741\" data-end=\"1757\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1759\" data-end=\"1884\"\u003e\u003cstrong data-start=\"1759\" data-end=\"1804\"\u003e32-Channel Temperature Acquisition System\u003c\/strong\u003e\u003cbr data-start=\"1804\" data-end=\"1807\"\u003eSupports simultaneous thermal monitoring across large battery testing setups.\u003c\/p\u003e\n\u003cp data-start=\"1886\" data-end=\"2015\"\u003e\u003cstrong data-start=\"1886\" data-end=\"1923\"\u003eThermocouple Sensor Compatibility\u003c\/strong\u003e\u003cbr data-start=\"1923\" data-end=\"1926\"\u003eCompatible with thermocouple sensors for wide-range temperature measurement applications.\u003c\/p\u003e\n\u003cp data-start=\"2017\" data-end=\"2112\"\u003e\u003cstrong data-start=\"2017\" data-end=\"2055\"\u003eWide Temperature Measurement Range\u003c\/strong\u003e\u003cbr data-start=\"2055\" data-end=\"2058\"\u003eSupports temperature acquisition from -200°C to 260°C.\u003c\/p\u003e\n\u003cp data-start=\"2114\" data-end=\"2258\"\u003e\u003cstrong data-start=\"2114\" data-end=\"2155\"\u003eFlexible Channel Mapping Architecture\u003c\/strong\u003e\u003cbr data-start=\"2155\" data-end=\"2158\"\u003eAuxiliary temperature channels can be assigned to any primary channel under the same middle machine.\u003c\/p\u003e\n\u003cp data-start=\"2260\" data-end=\"2376\"\u003e\u003cstrong data-start=\"2260\" data-end=\"2301\"\u003eIndustrial RS485 Communication System\u003c\/strong\u003e\u003cbr data-start=\"2301\" data-end=\"2304\"\u003eStable RS485 communication for professional battery testing integration.\u003c\/p\u003e\n\u003chr data-start=\"2378\" data-end=\"2381\"\u003e\n\u003ch3 data-section-id=\"q11yyz\" data-start=\"2383\" data-end=\"2404\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2386\" data-end=\"2404\"\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2406\" data-end=\"3395\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2406\" data-end=\"2435\"\u003e\n\u003ctr data-start=\"2406\" data-end=\"2435\"\u003e\n\u003cth data-start=\"2406\" data-end=\"2418\" data-col-size=\"md\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"2418\" data-end=\"2435\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2446\" data-end=\"3395\"\u003e\n\u003ctr data-start=\"2446\" data-end=\"2474\"\u003e\n\u003ctd data-start=\"2446\" data-end=\"2454\" data-col-size=\"md\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2454\" data-end=\"2474\" data-col-size=\"md\"\u003eCA-4032n-1U-T-TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2475\" data-end=\"2532\"\u003e\n\u003ctd data-start=\"2475\" data-end=\"2490\" data-col-size=\"md\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2490\" data-end=\"2532\" data-col-size=\"md\"\u003eAuxiliary Temperature Acquisition Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2533\" data-end=\"2550\"\u003e\n\u003ctd data-start=\"2533\" data-end=\"2544\" data-col-size=\"md\"\u003eChannels\u003c\/td\u003e\n\u003ctd data-start=\"2544\" data-end=\"2550\" data-col-size=\"md\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2551\" data-end=\"2578\"\u003e\n\u003ctd data-start=\"2551\" data-end=\"2563\" data-col-size=\"md\"\u003eTest Item\u003c\/td\u003e\n\u003ctd data-start=\"2563\" data-end=\"2578\" data-col-size=\"md\"\u003eTemperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2579\" data-end=\"2609\"\u003e\n\u003ctd data-start=\"2579\" data-end=\"2593\" data-col-size=\"md\"\u003eSensor Type\u003c\/td\u003e\n\u003ctd data-start=\"2593\" data-end=\"2609\" data-col-size=\"md\"\u003eThermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2610\" data-end=\"2661\"\u003e\n\u003ctd data-start=\"2610\" data-end=\"2642\" data-col-size=\"md\"\u003eTemperature Measurement Range\u003c\/td\u003e\n\u003ctd data-start=\"2642\" data-end=\"2661\" data-col-size=\"md\"\u003e-200°C to 260°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2662\" data-end=\"2718\"\u003e\n\u003ctd data-start=\"2662\" data-end=\"2685\" data-col-size=\"md\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2685\" data-end=\"2718\" data-col-size=\"md\"\u003e±1°C (within 2m cable length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2719\" data-end=\"2753\"\u003e\n\u003ctd data-start=\"2719\" data-end=\"2744\" data-col-size=\"md\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2744\" data-end=\"2753\" data-col-size=\"md\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2754\" data-end=\"2791\"\u003e\n\u003ctd data-start=\"2754\" data-end=\"2775\" data-col-size=\"md\"\u003eSampling Frequency\u003c\/td\u003e\n\u003ctd data-start=\"2775\" data-end=\"2791\" data-col-size=\"md\"\u003e10Hz (100ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2792\" data-end=\"2822\"\u003e\n\u003ctd data-start=\"2792\" data-end=\"2813\" data-col-size=\"md\"\u003eCommunication Mode\u003c\/td\u003e\n\u003ctd data-start=\"2813\" data-end=\"2822\" data-col-size=\"md\"\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2823\" data-end=\"2901\"\u003e\n\u003ctd data-start=\"2823\" data-end=\"2846\" data-col-size=\"md\"\u003eProtection Functions\u003c\/td\u003e\n\u003ctd data-start=\"2846\" data-end=\"2901\" data-col-size=\"md\"\u003eUpper temperature limit and lower temperature limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2902\" data-end=\"2930\"\u003e\n\u003ctd data-start=\"2902\" data-end=\"2916\" data-col-size=\"md\"\u003eData Export\u003c\/td\u003e\n\u003ctd data-start=\"2916\" data-end=\"2930\" data-col-size=\"md\"\u003eExcel, TXT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2931\" data-end=\"3005\"\u003e\n\u003ctd data-start=\"2931\" data-end=\"2949\" data-col-size=\"md\"\u003eChannel Mapping\u003c\/td\u003e\n\u003ctd data-start=\"2949\" data-end=\"3005\" data-col-size=\"md\"\u003eAuxiliary channels assignable to any primary channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3006\" data-end=\"3080\"\u003e\n\u003ctd data-start=\"3006\" data-end=\"3067\" data-col-size=\"md\"\u003eMaximum Temperature Auxiliary Channels per Primary Channel\u003c\/td\u003e\n\u003ctd data-start=\"3067\" data-end=\"3080\" data-col-size=\"md\"\u003eUp to 248\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3081\" data-end=\"3108\"\u003e\n\u003ctd data-start=\"3081\" data-end=\"3100\" data-col-size=\"md\"\u003eProtection Level\u003c\/td\u003e\n\u003ctd data-start=\"3100\" data-end=\"3108\" data-col-size=\"md\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3109\" data-end=\"3131\"\u003e\n\u003ctd data-start=\"3109\" data-end=\"3123\" data-col-size=\"md\"\u003eInput Power\u003c\/td\u003e\n\u003ctd data-start=\"3123\" data-end=\"3131\" data-col-size=\"md\"\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3132\" data-end=\"3168\"\u003e\n\u003ctd data-start=\"3132\" data-end=\"3156\" data-col-size=\"md\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"3156\" data-end=\"3168\" data-col-size=\"md\"\u003e0°C–40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3169\" data-end=\"3205\"\u003e\n\u003ctd data-start=\"3169\" data-end=\"3191\" data-col-size=\"md\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-start=\"3191\" data-end=\"3205\" data-col-size=\"md\"\u003e-10°C–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3206\" data-end=\"3255\"\u003e\n\u003ctd data-start=\"3206\" data-end=\"3227\" data-col-size=\"md\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd data-start=\"3227\" data-end=\"3255\" data-col-size=\"md\"\u003e≤70% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3256\" data-end=\"3303\"\u003e\n\u003ctd data-start=\"3256\" data-end=\"3275\" data-col-size=\"md\"\u003eStorage Humidity\u003c\/td\u003e\n\u003ctd data-start=\"3275\" data-end=\"3303\" data-col-size=\"md\"\u003e≤80% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3304\" data-end=\"3363\"\u003e\n\u003ctd data-start=\"3304\" data-end=\"3318\" data-col-size=\"md\"\u003eProbe Types\u003c\/td\u003e\n\u003ctd data-start=\"3318\" data-end=\"3363\" data-col-size=\"md\"\u003eType K Thermocouple \/ Type T Thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3364\" data-end=\"3395\"\u003e\n\u003ctd data-start=\"3364\" data-end=\"3378\" data-col-size=\"md\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd data-start=\"3378\" data-end=\"3395\" data-col-size=\"md\"\u003e1U Rack Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003eTechnical Specifications\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0977\/6355\/7714\/files\/639f6da53378bce.pdf?v=1780582951\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan style=\"text-decoration: underline;\"\u003eClick here\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3397\" data-end=\"3400\"\u003e\n\u003ch3 data-section-id=\"mgynq\" data-start=\"3402\" data-end=\"3434\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3405\" data-end=\"3434\"\u003eApplications \u0026amp; Industries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"3436\" data-end=\"3720\"\u003e\n\u003cli data-section-id=\"1maup9e\" data-start=\"3436\" data-end=\"3466\"\u003eBattery thermal monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"10grzhe\" data-start=\"3467\" data-end=\"3505\"\u003eLithium-ion battery safety testing\u003c\/li\u003e\n\u003cli data-section-id=\"1v4672u\" data-start=\"3506\" data-end=\"3534\"\u003eThermal runaway analysis\u003c\/li\u003e\n\u003cli data-section-id=\"1jbf3i4\" data-start=\"3535\" data-end=\"3572\"\u003eEnvironmental chamber integration\u003c\/li\u003e\n\u003cli data-section-id=\"9nljoa\" data-start=\"3573\" data-end=\"3615\"\u003eBattery module temperature acquisition\u003c\/li\u003e\n\u003cli data-section-id=\"1qgkt6o\" data-start=\"3616\" data-end=\"3649\"\u003eEnergy storage system testing\u003c\/li\u003e\n\u003cli data-section-id=\"kvjpm8\" data-start=\"3650\" data-end=\"3678\"\u003eBattery R\u0026amp;D laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1i8uhgf\" data-start=\"3679\" data-end=\"3720\"\u003eIndustrial battery validation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3722\" data-end=\"3725\"\u003e\n\u003ch3 data-section-id=\"elc90z\" data-start=\"3727\" data-end=\"3737\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3730\" data-end=\"3737\"\u003eFAQ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-section-id=\"mfiqv0\" data-start=\"3739\" data-end=\"3800\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3743\" data-end=\"3800\"\u003eHow many temperature channels does this unit support?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3801\" data-end=\"3867\"\u003eThe system supports 32 independent auxiliary temperature channels.\u003c\/p\u003e\n\u003cp data-section-id=\"1ses339\" data-start=\"3869\" data-end=\"3919\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3873\" data-end=\"3919\"\u003eWhat temperature sensor type is supported?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"3920\" data-end=\"4001\"\u003eThe unit supports thermocouple sensors including Type K and Type T thermocouples.\u003c\/p\u003e\n\u003cp data-section-id=\"n6tw21\" data-start=\"4003\" data-end=\"4053\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4007\" data-end=\"4053\"\u003eWhat is the temperature measurement range?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"4054\" data-end=\"4119\"\u003eThe system supports temperature acquisition from -200°C to 260°C.\u003c\/p\u003e\n\u003cp data-section-id=\"8hxxrk\" data-start=\"4121\" data-end=\"4175\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4125\" data-end=\"4175\"\u003eCan the auxiliary channels be assigned freely?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"4176\" data-end=\"4279\"\u003eYes, auxiliary temperature channels can be mapped to any primary channel under the same middle machine.\u003c\/p\u003e\n\u003cp data-section-id=\"l11wdp\" data-start=\"4281\" data-end=\"4333\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4285\" data-end=\"4333\"\u003eWhat communication method does the unit use?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"4334\" data-end=\"4424\"\u003eThe system uses RS485 communication for integration with Neware battery testing equipment.\u003c\/p\u003e","brand":"Cell Lab","offers":[{"title":"Default Title","offer_id":53644832244050,"sku":"NW0052","price":2365.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/6355\/7714\/files\/Neware_CA-4032n-1U-T-TC_Auxiliary_Temperature_Unit_32Ch.jpg?v=1780583095","url":"https:\/\/celllab.co.uk\/products\/neware-ca-4032n-1u-t-tc-auxiliary-temperature-unit-32ch","provider":"Cell Lab Ltd","version":"1.0","type":"link"}